The mainspring broke after a couple days of running. I'll change it out, then start the test cycle over.
Job Number 250148
The mainspring broke after a couple days of running. I'll change it out, then start the test cycle over.
Job Number 220082
The first full wind after assembly broke the mainspring. Well better now than after it's sent home.
Follow the album for this project here:
Job Number 220002, Continued
Miraculously, a source turned up with a cache of NOS parts for this complication. They weren't cheap, but they're here and it looks like it will all work.
Here is the slight gap, visible at the left end of the upper plate as it sits on the up/down assembly. It seems like the pinion needs to be shorter by that amount.
That hook attaches to a machined-in raised portion at the end of the slot at the outside edge of the barrel.These barrels are really, really hard to find if that hook area breaks or wears. It looks like a tab cut as part of the slot that could be duplicated, but it is isn't. It is manufactured into the floor or the barrel. I have not been able to succeed at repairing one of these in a way that would last.
Job Number 220006
Well that's a broken mainspring ... Also a broken tooth on the ratchet wheel.
Over on Instagram I received several comments and a couple direct messages about this image asking how this could have happened to a mainspring.
Although this is a spectacular case, it's not uncommon with old steel springs. The watch was wound up when it stopped running for what ever reason. The spring was at least mostly coiled in toward the middle. It partly "set" in that shape over time, so tension on the coils was uneven. There was some rust that weakened the material. The outer coils just gave way at some point and opened up, while parts of the spring stayed "wound" in the middle. The weakness and uneven tension cause multiple breaks because the spring can't uncoil.
This keyless works design in many smaller Elgins is something to be dreaded. It very often works poorly as it depends on springs and other parts having just right tension and very low wear. Thankfully this one is almost like new and works perfectly.
This movement is a grade 289 Elgin, 6 size, 7 jewels, made about 1907.
Everything is in really nice condition. There's a slight grain to the finish on the plates.
I ended up replacing the upper balance jewel due to just a bit too much wear. A hairspring adjustment was also called for, and I am pretty sure that still isn't quite right. It's always a pain with these smaller Elgins... I'm leaving it in the case running for awhile, so the stem will be in winding mode.
It took quite a lot of work to get the rate in the ballpark, but it's finally ready for a few days of testing. Mechanically, just as far as running correctly, it's very good.
Job Number 210157, Elgin Grade 240, B. W. Raymond
It's a motor barrel so the barrel came right apart as I disassembled.
Broken balance staff...The movement is an Elgin grade 240, 18 size, 19 jewels, B. W. Raymond model, made about 1909.
The bevel pinion and clutch failed to rest in contact in winding mode. The movement wouldn't wind. Odd...
Running well so far...
I replaced one of the plate screws that was an incorrect style, and added a couple of timing washers. It's now ready for a few days of testing.
Job Number 210153, Hampden Special - Before
Unfortunately this spring is a bit scarce. I don't think I have one. The hunt is on.
These are some "before" pictures of this next movement. It's an 18 size Hampden Special, 17 jewels, made about 1896.Clearly this one has not been cleaned in a long while.
Is that literally saw dust in there?
https://photos.app.goo.gl/2NgeUAoC7LyX8FV98
Job Number 210151, Elgin Grade 478
It had a broken mainspring but no other problems. Can you spot the break?
Both case and the movement are marked B. W. Raymond. The case mark is rather rare.
https://photos.app.goo.gl/VWfGeppiZposjhvB7
Job Number 190043
The crystals are not supposed to be this way, they were originally clear. Over decades these early types of plastic decayed and changed. While doing so, they gave off a corrosive gas that very commonly, as is the case on this Hamilton, severely damages the hands and often the dial too. In the worst case, the corrosion will extend to internal parts inside the movement through the center of the dial.
It's temping to think that plastic crystals are always "cheap" replacements. But this is not necessarily so. Plastic crystals were considered a technological improvement over glass as they were said to be "unbreakable".
Some people prefer to leave these crystals on as original. This may be fine. Many believe that the degassing stopped long ago. On the other hand, some say that the old plastic crystals should always be replaced to avoid the risk of further damage. I don't know. This plastic crystal was replaced with glass.
Broken mainspring...
The train...
The Hamilton pallet fork and pallet bridge...
Hamilton hairspring stud clamps, which are pretty small, have two small screws, one for each side of the stud. It always takes a little holding of breath to get these placed with the balance bouncing around, but there are a few tricks that make it easier.
Blog Archive
-
▼
2026
(112)
-
▼
September
(15)
- New Arrival, Job Number 260041
- New Arrival, Job Number 260040
- Job Number 260030
- Job Number 260030
- New Arrival, Job Number 260034
- New Arrival, Job Number 260032
- Job Number 260030
- Job Number 260028
- Job Number 260028
- Job Number 260026
- Job Number 260026
- Job Number 260010
- Job Number 260022
- Job Number 260024
- Job Number 260024, The Geneva Stop Installed
-
▼
September
(15)




























